CHEN Jian-Ping. Rapid Detection of Bean Yellow Mosaic Virus, Potato Virus M and Oat Mosaic Virus Using Immunosorbent Electronmicroscopy[J]. Virologica Sinica, 1991, 6(1).
Citation: CHEN Jian-Ping. Rapid Detection of Bean Yellow Mosaic Virus, Potato Virus M and Oat Mosaic Virus Using Immunosorbent Electronmicroscopy .VIROLOGICA SINICA, 1991, 6(1) : 53.

应用免疫电镜技术快速检测菜豆黄花叶病毒、马铃薯M病毒和燕麦花叶病毒

  • 应用免疫吸附电流技术(ISEM)可有效地检测腐汁液中的菜豆黄花叶病毒(BYMV)、马铃薯M病毒(PVM)和燕麦花叶病毒(OMV)。BYMV,PVM和OMV三种抗血清的适宜工作浓度和对铜网的适宜包被时间均为1000倍和1小时,对同源病毒的适宜捕获时间分别为4℃下2、2和8小时。PVM和OMV的病汁液检测灵敏度均为稀释4000倍,而BYMV病汁液稀释16000倍时还能检测到少量病毒料子。ISEM捕获法和修饰法的结果表明,这三种病毒之间无血清学交叉反应。

Rapid Detection of Bean Yellow Mosaic Virus, Potato Virus M and Oat Mosaic Virus Using Immunosorbent Electronmicroscopy

  • Bean yellow mosaic virus (BYMV), potato virus M(PVM) and oat mosaic virus (OMV)were rapidly detected in infected leaf extracts using immunosorbent electron microscopy. The suitable dilution and time for coating the three antisera in carbon coated grids were 1000 and 1h at room temperature. The suitable trapping time for BYMV, PVM and OMV were 2,2 and 8h respectively at 4℃. The detective sensitivities in leaf saps were 4000 dilutions for PVM and OMV, and a few virus particles could still be seen at the dilut...

  • 加载中
  • 加载中

Article Metrics

Article views(3740) PDF downloads(855) Cited by(0)

Related
Proportional views
    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Rapid Detection of Bean Yellow Mosaic Virus, Potato Virus M and Oat Mosaic Virus Using Immunosorbent Electronmicroscopy

    • 1. Virology Laboratory

    Abstract: Bean yellow mosaic virus (BYMV), potato virus M(PVM) and oat mosaic virus (OMV)were rapidly detected in infected leaf extracts using immunosorbent electron microscopy. The suitable dilution and time for coating the three antisera in carbon coated grids were 1000 and 1h at room temperature. The suitable trapping time for BYMV, PVM and OMV were 2,2 and 8h respectively at 4℃. The detective sensitivities in leaf saps were 4000 dilutions for PVM and OMV, and a few virus particles could still be seen at the dilut...

    Relative (20)

    目录

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return