HONG Shi-Wen, HE Hong-Xia, SHU Feng-Lan and LIN Tao. A Study on the Detection of Antibodies to HIV Type 1and Type 2 by Using Synthetic Peptides[J]. Virologica Sinica, 1995, 10(3).
Citation: HONG Shi-Wen, HE Hong-Xia, SHU Feng-Lan, LIN Tao. A Study on the Detection of Antibodies to HIV Type 1 and Type 2 by Using Synthetic Peptides .VIROLOGICA SINICA, 1995, 10(3) : 236.

人工合成多肽检测抗HIV-1和HIV-2抗体的研究

  • 采用固相法合成HIV-1和HIV-2两个多肽,建立了用混合多肽为包被抗原检测HIV-1和HIV-2感染的间接酶联免疫吸附法。检测46份抗HIV-1和HIV-2抗体阳性血清标本以及94份对照血清标本,与UBI试剂比较,其阳性符合率为97.8%,阴性符合率为100%,总符合率为99.3%。实验结果表明,此法可用于HIV-1和HIV-2感染的检测。

A Study on the Detection of Antibodies to HIV Type 1 and Type 2 by Using Synthetic Peptides

  • Two peptides of human immunodeficiency virus(HIV)type 1 and type 2 were synthe-sized by solid-phase method. An indirect enzyme-linked immunosorbent assay(ELISA)em-ploying these peptides as an antigen adsorbent was developed to detect the infections of HIV-1 and HIV-2.A comparison of our reagent with UBI reagent in detection of 46 positive serumspecimens and 94 negative control serum specimens for HIV-1 and HIV-2 showed that theconcident rate for positive was 97.8%, for negative was 100%,and the general coincidentrate was 99.3%. The results indicated that this method can be used in detection for infectionsof HIV-1 and HIV-2.

  • 加载中
  • 加载中

Article Metrics

Article views(3713) PDF downloads(811) Cited by(0)

Related
Proportional views
    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    A Study on the Detection of Antibodies to HIV Type 1 and Type 2 by Using Synthetic Peptides

    • 1. d hospital of PLA,Beijing 100039

    Abstract: Two peptides of human immunodeficiency virus(HIV)type 1 and type 2 were synthe-sized by solid-phase method. An indirect enzyme-linked immunosorbent assay(ELISA)em-ploying these peptides as an antigen adsorbent was developed to detect the infections of HIV-1 and HIV-2.A comparison of our reagent with UBI reagent in detection of 46 positive serumspecimens and 94 negative control serum specimens for HIV-1 and HIV-2 showed that theconcident rate for positive was 97.8%, for negative was 100%,and the general coincidentrate was 99.3%. The results indicated that this method can be used in detection for infectionsof HIV-1 and HIV-2.