Li-Jing-Yun, WANG Hong-Xia and BAO Zuo-Xi. The Establishment and Application of Immunofluorescence Assay for Detection of Antibodies to HIV-1[J]. Virologica Sinica, 1997, 12(4).
Citation: Li-Jing-Yun, WANG Hong-Xia, BAO Zuo-Xi. The Establishment and Application of Immunofluorescence Assay for Detection of Antibodies to HIV-1 .VIROLOGICA SINICA, 1997, 12(4) : 371.

免疫荧光检测HIV-1抗体方法的建立和应用

  • 免疫荧光法检测HIV抗体是确认HIV感染的方法之一[l],与蛋白印迹法相比,它的特异性更高,易于鉴别非特异反应,更为经济、快速、容易操作。为了拥有更多的HIV抗体检测手段,我们用感染和未感染HIV-l的HeLaCD“细胞制备抗原片,建立了免疫荧光检测HIV抗体的方法,并进行了初步应用。材料和方法1细胞和病毒HeLaCD4”细胞,引自美国BruceChesebro博士的实验室,用含10%热灭活小牛血清的RPMI1640培养基培养和传代。HIV-l株引自美国。2血清艾滋诊断试剂国家参比品,批号9602Z16份经蛋白印迹确认的HIV抗体阳性血清;10份健康人血清Z10份责疽及肝炎病人血清;月份HIV抗体初筛阳性血清。3制备抗原片Hel,。CD4”细胞长成单层后,加入05ml。滴度为10‘TCID50的HIV一三,吸附lh后加入新鲜培养基,37℃培养3d将感染的细胞用025%的胰酶消化、洗涤,稀释成浓度为5。104细胞/mL的细胞是液,同样处理一瓶未感染的细胞,将感染和未感染的细胞等量混合,15“滴入Ic孔镀膜载玻片上,37℃、5%Cq条件下培养8h细胞长成本层后,用冷丙酮固定10min,封片,置一20℃保存备用。4...

The Establishment and Application of Immunofluorescence Assay for Detection of Antibodies to HIV-1

  • Using the mixture of HIV -1 infected and no - infected HeLa CD4+ cells, the antigen slides were prepared and the immunofluorescence assay for detection of antibodies to human immunode-ficiency virus type 1 was established. Seventy - seven serum samples including the national stan-dard reference of HIV antibody reagents were tested. The sensitivity and specificity were 96. 4 %and 100%, respectively. Compared with the confirmation test of Western Blot, the coincident rate was 92. 6 %. The results indicated th...

  • 加载中
  • 加载中

Article Metrics

Article views(3856) PDF downloads(769) Cited by(0)

Related
Proportional views
    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    The Establishment and Application of Immunofluorescence Assay for Detection of Antibodies to HIV-1

    • 1. Institute of Microbiology and Epidemiology

    Abstract: Using the mixture of HIV -1 infected and no - infected HeLa CD4+ cells, the antigen slides were prepared and the immunofluorescence assay for detection of antibodies to human immunode-ficiency virus type 1 was established. Seventy - seven serum samples including the national stan-dard reference of HIV antibody reagents were tested. The sensitivity and specificity were 96. 4 %and 100%, respectively. Compared with the confirmation test of Western Blot, the coincident rate was 92. 6 %. The results indicated th...

    目录

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return